Default Jet pumps

This is just me complaining but when we'll companies and other plumbers install new pumps why not install ported check valve so I can check vacuum to see if pump is pulling makes it a lot easier to trouble shoot just a pet pev of mine
plumbob2008 is offline   Reply With Quote

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Sponsored Links
Advertisement
 
Old 09-08-2015, 06:31 PM   #2
Senior Member
 
AWWGH's Avatar
 
Join Date: May 2011
Location: Connecticut
Posts: 982

View AWWGH's Photo Album My Photos
Default

Quote:
Originally Posted by plumbob2008
This is just me complaining but when we'll companies and other plumbers install new pumps why not install ported check valve so I can check vacuum to see if pump is pulling makes it a lot easier to trouble shoot just a pet pev of mine
Install a check valve where? Single of double line?
AWWGH is offline   Reply With Quote
Old 09-08-2015, 07:21 PM   #3
Senior Member
 
Join Date: Sep 2013
Location: Southwastern Ontario the land of the wind turbines
Posts: 826

View Dpeckplb's Photo Album My Photos
Default

I only use a foot valve at the bottom of well. No other check valve. I agree though sometimes it would make trouble shooting easier. However up here it would be the difference of putting in a pump or not putting in a pump.
Dpeckplb is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 09-08-2015, 07:24 PM   #4
Senior Member
 
AWWGH's Avatar
 
Join Date: May 2011
Location: Connecticut
Posts: 982

View AWWGH's Photo Album My Photos
Default

Quote:
Originally Posted by Dpeckplb
I only use a foot valve at the bottom of well. No other check valve. I agree though sometimes it would make trouble shooting easier. However up here it would be the difference of putting in a pump or not putting in a pump.
Same, we don't add a check valve at the pump here.
AWWGH is offline   Reply With Quote
Old 09-08-2015, 08:50 PM   #5
Senior Member
 
Michaelcookplum's Avatar
 
Join Date: May 2011
Location: Northern Virginia
Posts: 1,152

View Michaelcookplum's Photo Album My Photos
Default

Same reason plumbers don't install a shut off valve before and after a PRV. Would make the next guys job so much easier 10 years down the road. Same reason why we don't take a match to a $100 bill. I understand what your saying but I think your statement is just wishful thinking.

Charge more $ to install one so you can test it easier next time you come back!! Or just do it for free for the next guy
__________________
Mike Cook
Michaelcookplum is offline   Reply With Quote
The Following 2 Users Say Thank You to Michaelcookplum For This Useful Post:
Cajunhiker (09-08-2015)
Old 09-08-2015, 11:49 PM   #6
Junior Member
 
Join Date: Jul 2015
Posts: 27

View plumbob2008's Photo Album My Photos
Default

Sorry guy should have explained more here in Delaware most if not all wells are shallow wells high water table here I like check valve at pump and also union between pump and check valve no prv here home on city watet max pressure is 50 psi
plumbob2008 is offline   Reply With Quote
Old 09-08-2015, 11:52 PM   #7
Junior Member
 
Join Date: Jul 2015
Posts: 27

View plumbob2008's Photo Album My Photos
Default

Also hate 2 pipe system need to have both pipes full of water to prime that's a lot of water
plumbob2008 is offline   Reply With Quote
Old 09-10-2015, 09:21 PM   #8
Senior Member
 
Join Date: Sep 2013
Location: Southwastern Ontario the land of the wind turbines
Posts: 826

View Dpeckplb's Photo Album My Photos
Default

If the foot valve is properly working it is a check valve. Adding a second check valve is redundant and could cause more grief. It could potentially cause a 1/2 HP not be big enough depends on the depth or travel.
I agree deep well twin lines are a total pita to line up ESP. In a tiny pump house. Get yourself a positive displacement handpump makes priming a breeze.
Dpeckplb is offline   Reply With Quote
Old 09-10-2015, 10:01 PM   #9
Senior Member
 
AWWGH's Avatar
 
Join Date: May 2011
Location: Connecticut
Posts: 982

View AWWGH's Photo Album My Photos
Default

Quote:
Originally Posted by plumbob2008
Also hate 2 pipe system need to have both pipes full of water to prime that's a lot of water
You go deeper than 25 feet or so with a jet pump it's a two line.

We still have plenty around here- they are the worsted after hours calls.
AWWGH is offline   Reply With Quote
Old 09-15-2015, 07:59 AM   #10
Senior Member
 
Join Date: May 2014
Location: Rhode Island
Posts: 303

View paultheplumber1's Photo Album My Photos
Default

Nothing worse than messing with a deep well jet when it's cold outside and it nearing the end of the day. Especially when you have to pull it twice because that one tiny chunk of rust landed perfectly in the nozzle.
paultheplumber1 is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
pressure boosting pumps plumbingdept Residential Plumbing 2 08-16-2015 02:15 PM


All times are GMT -4. The time now is 04:19 AM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2019, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | ElectricianTalk.com | HVACSite.com | PaintTalk.com | RoofingTalk.com