In order to fix a leaking American Standard Faucet on a roman tub this is what you have to do. It was installed 4 years ago.


Leaking diverter, remove spout....Ok it worked, the store gave her an incorrect longer stem...I swapped the o-rings. Turn the water on, no leaks until called 40 minutes later and her ceiling is wet. So I look at her instructions sheet the spout shank has O-ring under the tub...Great Impossible to get to!

The second complaint the handles were were opening the wrong way. The instruction says to turn the escutcheon and pull on the handle....Handles seized after 4 years of installation...Great!


So today I repaired the faucet completely as if it was new. All you have to do is cut a hole in the tile skirt and few maneuvers to to get to the shank O-ring.




chonkie, Debo22 and MACPLUMB777 like this.
Tango is offline   Reply With Quote
The Following User Says Thank You to Tango For This Useful Post:
Tommy plumber (09-30-2018)

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Sponsored Links
Advertisement
 
Old 09-28-2018, 08:44 PM   #2
Moderator Wizard
 
Tango's Avatar
 
Join Date: Jan 2018
Location: Québec
Posts: 6,819

View Tango's Photo Album My Photos
Default

Got to go back on monday so I'll take pics of the repair. Did I ever say this brand sucks? On second thought, I hope I get more of these if you know what I mean...
MACPLUMB777 and Mikeob1998 like this.
Tango is offline   Reply With Quote
Old 09-29-2018, 11:37 AM   #3
Senior Member
 
Alan's Avatar
 
Join Date: Jun 2008
Location: California
Posts: 1,401

View Alan's Photo Album My Photos
Default

I just have to say they don't make stuff like they used to.

I've repaired tons of american standard faucets/tub valves. Sometimes yeah they get abused and let to leak longer than they should and then they are seized and difficult to disassemble.

I wouldn't call the brand junk though.
chonkie and skoronesa like this.
__________________
Journeyman Plumber
Alan is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 09-29-2018, 12:45 PM   #4
Senior Member
 
The Dane's Avatar
 
Join Date: Feb 2015
Location: NW Minnesota
Posts: 1,074

View The Dane's Photo Album My Photos
Default

I am not a fan of American standard at all. I would take it over some of the big box stores brands like p-fister. I much prefer Moen and if I get a call for a leaky faucet and it's an American standard I would offer to repair it but also tell the customer that it can also be replaced with a new and better faucet if they so choose. If it's a box store brand I get called out for I immediately tell the customer that it's going to be replaced unless they want to deal with the headache of finding parts and doing it themselves

Sent from my BLN-L24 using Tapatalk
The Dane is online now   Reply With Quote
Old 09-29-2018, 08:14 PM   #5
Senior Member
 
Join Date: Jan 2012
Location: cold north land
Posts: 841

View fixitright's Photo Album My Photos
Default

Drain cleaning is much easier. Sometimes.
czplumbing and skoronesa like this.
fixitright is offline   Reply With Quote
Old 09-29-2018, 10:59 PM   #6
Senior Member
 
Alan's Avatar
 
Join Date: Jun 2008
Location: California
Posts: 1,401

View Alan's Photo Album My Photos
Default

Quote:
Originally Posted by fixitright View Post
Drain cleaning is much easier. Sometimes.
skoronesa likes this.
__________________
Journeyman Plumber
Alan is offline   Reply With Quote
Old 09-30-2018, 08:52 AM   #7
Moderator Wizard
 
Tango's Avatar
 
Join Date: Jan 2018
Location: Québec
Posts: 6,819

View Tango's Photo Album My Photos
Default

Quote:
Originally Posted by fixitright View Post
Drain cleaning is much easier. Sometimes.
Job like those I get home so god damn tired I had to lay down. I even overslept 2 hours on saturday morning.

I'll take pictures next time to show how many tools and stuff to swap one out.
Tango is offline   Reply With Quote
Old 09-30-2018, 09:06 AM   #8
Senior Member
 
ShtRnsdownhill's Avatar
 
Join Date: Jan 2016
Location: Long Island, NY
Posts: 8,227

View ShtRnsdownhill's Photo Album My Photos
Default

Quote:
Originally Posted by Alan View Post
I just have to say they don't make stuff like they used to.

I've repaired tons of american standard faucets/tub valves. Sometimes yeah they get abused and let to leak longer than they should and then they are seized and difficult to disassemble.

I wouldn't call the brand junk though.
KOLHER SUCKS !!!!!..it looks good and will last if you dont use it, but they suck every way it can..lol...
Tango likes this.
ShtRnsdownhill is online now   Reply With Quote
Old 09-30-2018, 09:33 AM   #9
Moderator Wizard
 
Tango's Avatar
 
Join Date: Jan 2018
Location: Québec
Posts: 6,819

View Tango's Photo Album My Photos
Default

I replaced that faucet with a Moen she bought. First time its one of those you have to solder the parts. It was easier than those freaking flex hose in a tight space and where stubs can never be tight and after a few month everything is loose and wobbles.

I still have to go back though, the pyramid escutcheons/handle assembly are just screwed in place by hand and you can turn them easily. The woman says they are loose and is scared water will drip under them into the main floor. I told her if I put them tighter the square radius will scratch the tub, but she's the customer!

I will be siliconing them tomorrow EVEN Though I did like the instruction that said to put silicone on the washers under the tub which I think is intended create a water seal. I'll do the same to the spout.

Should I put putty instead of silicone on top of the tub and underneath the escutcheons? Silicone may make them hard to pull out in the future. (putty might shear out when turning the escutcheons/handle assembly into place)
Tango is offline   Reply With Quote
Old 09-30-2018, 05:34 PM   #10
Senior Member
 
Alan's Avatar
 
Join Date: Jun 2008
Location: California
Posts: 1,401

View Alan's Photo Album My Photos
Default

Seems like nowadays everything in terms of trim kit is coming with it's own o-ring or built in foam gasket.

I also can't stand that square crap for that reason, and I also do not like mounting tub trim to the fiberglass. :(

I would do whatever the mfg suggests and CYA.
__________________
Journeyman Plumber
Alan is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
American Standard widespread faucet ID help spamispeople General Plumbing Discussion 0 04-06-2018 08:57 AM
Strange American Standard fill valve MECH-MAN Residential Plumbing 1 04-29-2017 11:50 AM
American standard "double vision" Plumbersteve Plumbing Pictures 16 01-22-2016 03:15 PM
American standard dclarke General Plumbing Discussion 33 11-23-2015 10:46 PM
Help! Old American Standard Tub Handle Plumber General Plumbing Discussion 7 08-10-2015 10:47 AM


All times are GMT -4. The time now is 11:44 PM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2020, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | ElectricianTalk.com | HVACSite.com | PaintTalk.com | RoofingTalk.com