Default Any Illinois Plumbers want to share their opinion?

Today I had a Repipe that involved lifting and reworking some section of copper drainage. The original layout was very hard to transition into something that could be considered code compliant. I could not work above on the second floor, and basically had to make chicken **** into chicken salad so that it would fit inside of the joists without back pitching vents/drainage and keeping enough meat on the joist.

Heel inlet 90 on its side picking up a dry vent.. am I cutting this **** out? Or do you think inspector will have a ❤️. Family still using upstairs bathrooms daily..
Attached Thumbnails
Any Illinois Plumbers want to share their opinion?-61426e11-7c7a-4eb2-b28b-492f958522d2_1574741406592.jpeg  

Any Illinois Plumbers want to share their opinion?-ea2bcb8d-df2f-4317-89fd-20cdff915c21_1574741435199.jpeg  

Any Illinois Plumbers want to share their opinion?-56f77e9b-e512-475a-993d-3518153ff2d8_1574741458828.jpg  

Any Illinois Plumbers want to share their opinion?-518558e2-f592-43a4-bb96-104ed1aaf8d0_1574741499917.jpeg  

Any Illinois Plumbers want to share their opinion?-c9b1b396-cc4c-4d2d-b883-37de28f157ff_1574741518359.jpeg  

MikeThePiper is online now   Reply With Quote

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Sponsored Links
Advertisement
 
Old Today, 12:12 AM   #2
Junior Member
 
MikeThePiper's Avatar
 
Join Date: Oct 2019
Posts: 13

View MikeThePiper's Photo Album My Photos
Default

Heel inlet on side
Attached Thumbnails
Any Illinois Plumbers want to share their opinion?-26d30887-b1e4-48d3-b89f-604a443d6f11_1574741569215.jpg  

MikeThePiper is online now   Reply With Quote
The Following User Says Thank You to MikeThePiper For This Useful Post:
MASTRPLUMB (Today)
Old Today, 07:27 AM   #3
Senior Member
 
Join Date: Nov 2015
Posts: 329

View Toli's Photo Album My Photos
Default Any Illinois Plumbers want to share their opinion?

I think the heel inlet orientation is fine except the 2” is supposed to be wet. Is the other 2” that the 3x2 wye is grabbing wet? If so you could switch them. Or the 2” that’s right beside it?
Toli is online now   Reply With Quote
Sponsored Links
Advertisement
 
Old Today, 09:26 AM   #4
GAN
Super Moderator
 
GAN's Avatar
 
Join Date: Jul 2012
Location: St. Louis Metro
Posts: 1,950

View GAN's Photo Album My Photos
Default

What a nightmare on Elm Street. For what you had it is a major clean up. Drilling the floor joists, are you in the mid 30% span of the member? if not you have diminished the integrity of the joist.

Is there a main stack I am missing?

Where are your cleanouts? (like someone is really going to open one up overhead.

Kudo's for using the raised bead adapters.

Hate to say it, but this is a case for leaving the system running under the joists and tell them to suck it up and put a soffit or drop ceiling back. Would have been a much cleaner job. Great job of making your own puzzle pieces fit.
__________________
Il. Lic.# 058-106725, Il. C.C.D.I. Lic. # XCO396
Remember valor, honor, independence, family & clan;
I do whenever I hear the ceol mor,
the "great music" of the Highland bagpipe. I swear upon the holy iron of my dirk that I will not forget.
GAN is offline   Reply With Quote
Old Today, 10:56 AM   #5
Senior Member
 
ShtRnsdownhill's Avatar
 
Join Date: Jan 2016
Location: Long Island, NY
Posts: 5,455

View ShtRnsdownhill's Photo Album My Photos
Default

talk about getting 10 pounds of schit in a 5 pound bag....if you wanted you could have sistered the floor joists before re-piping to add some support, but that could have made some of the fittings not fit...we cant use those heal 90s so the one you used I would have had to make fit a y in the middle bay...just charge enough for the aggravation of doing it...
__________________
You cant cure stupid, only kill it..
ShtRnsdownhill is online now   Reply With Quote
Old Today, 11:05 AM   #6
Junior Member
 
MikeThePiper's Avatar
 
Join Date: Oct 2019
Posts: 13

View MikeThePiper's Photo Album My Photos
Default

Quote:
Originally Posted by GAN View Post
What a nightmare on Elm Street. For what you had it is a major clean up. Drilling the floor joists, are you in the mid 30% span of the member? if not you have diminished the integrity of the joist.

Is there a main stack I am missing?

Where are your cleanouts? (like someone is really going to open one up overhead.

Kudo's for using the raised bead adapters.

Hate to say it, but this is a case for leaving the system running under the joists and tell them to suck it up and put a soffit or drop ceiling back. Would have been a much cleaner job. Great job of making your own puzzle pieces fit.
The main stack may or may not be visible but it’s basically dropping down into the joist with a 90, kind of looks like a w.c.

The main stack follows through the joists and drops into basement. The cleanout is on a combo below and once again like 2’ from floor on vertical stack.

I tried to argue my case with the contractor but he was all in. I mentioned the joists, and 4” holes to fit a 3” hub etc etc, he confirmed everything with an “architect”. If the inspector fails, we will have to rip upstairs out.

Honestly, I must have done something horrible in my past life to have gotten this job 😂
MikeThePiper is online now   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



All times are GMT -4. The time now is 12:10 PM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2019, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2019 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | ElectricianTalk.com | HVACSite.com | PaintTalk.com | RoofingTalk.com