Default Cross over valve

I was on another forum and this term came up I have not heard
of this..... I do alot more commercial stuff this was used in a home
domestic water heater with a pump in a home
geofd is offline   Reply With Quote

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Sponsored Links
Advertisement
 
Old 02-23-2018, 09:15 AM   #2
Senior Member
 
Join Date: Jul 2016
Posts: 151

View WashingtonPlung's Photo Album My Photos
Default

Quote:
Originally Posted by geofd View Post
I was on another forum and this term came up I have not heard
of this..... I do alot more commercial stuff this was used in a home
domestic water heater with a pump in a home
Maybe you should explain what this valve does. Becuase i'm sure some of us have heard it by another name.

Is it a mixing valve?
WashingtonPlung is offline   Reply With Quote
Old 02-23-2018, 10:38 AM   #3
Senior Member
 
chonkie's Avatar
 
Join Date: Jul 2014
Location: North Texas
Posts: 3,118

View chonkie's Photo Album My Photos
Default

Probably referring to recirc system with no dedicated return line, the little block that's installed at the farthest point from the w/h, usually a lav, and it allows the hot to use the cold line for return to w/h. Grundfos has one you install the pump on the w/h and add the block.
Debo22 and MACPLUMB777 like this.
chonkie is offline   Reply With Quote
Sponsored Links
Advertisement
 
Old 02-23-2018, 11:20 AM   #4
The Old (antique) Master
 
PLUMBER_BILL's Avatar
 
Join Date: Oct 2009
Location: ALLENTOWN, PA
Posts: 2,246

View PLUMBER_BILL's Photo Album My Photos
Default

Quote:
Originally Posted by chonkie View Post
Probably referring to recirc system with no dedicated return line, the little block that's installed at the farthest point from the w/h, usually a lav, and it allows the hot to use the cold line for return to w/h. Grundfos has one you install the pump on the w/h and add the block.
Chonkie way back ... early 2015 this was a pretty big discussion.

Here is what I said then.Originally Posted by Best Darn Sewer
All this is news to me. I never knew the Grundfos comfort system bypass had a thermal control valve. Even when I've spoken with tech support in the past they just said its a simple check valve. Are y'all sure its thermally controlled? Being the timer on the unit controls the pump why would it be thermally controlled?


The timer on the pump is to turn it on lets say 6:45 A.M. and then turn if off lets say 9:39 A.M. Pump can be turned on and off according to life style. Control valve shuts off when hot water detected at faucet.


__________________
Bill Parr LMP
www.parrsplumbing.net
For my alternate web site, click on ...
A little of this and a little of that

The Following 2 Users Say Thank You to PLUMBER_BILL For This Useful Post: Best Darn Sewer (10-04-2015), chonkie (10-09-2015)
chonkie likes this.
__________________
Bill Parr LMP
www.parrsplumbing.net
For my alternate web site, click on ...
A little of this and a little of that
PLUMBER_BILL is offline   Reply With Quote
The Following User Says Thank You to PLUMBER_BILL For This Useful Post:
MACPLUMB777 (02-23-2018)
Old 02-23-2018, 01:29 PM   #5
Junior Member
 
Join Date: Feb 2018
Location: framingham ma
Posts: 10

View geofd's Photo Album My Photos
Default

Quote:
Originally Posted by geofd View Post
I was on another forum and this term came up I have not heard
of this..... I do alot more commercial stuff this was used in a home
domestic water heater with a pump in a home
I read that when there is no return for domestic he
there is a fitting that's installed under a lav (I don't know
how to post pics) when the pump on the water heater is on
it turns part of the cw into a hot return/as soon as a fixture is
used it shuts down that valve and it goes back to it origanal state
I will get the name of the one I found and post it

check out ready temp.com

Last edited by geofd; 02-23-2018 at 01:33 PM.. Reason: More info
geofd is offline   Reply With Quote
Old 02-23-2018, 02:27 PM   #6
Senior Member
 
chonkie's Avatar
 
Join Date: Jul 2014
Location: North Texas
Posts: 3,118

View chonkie's Photo Album My Photos
Default

I remember that discussion. After taking one apart and testing it, we did conclude that it is not just a simple check valve and it actually closes off when the h2o reaches a certain temp. Don't know what the temp is but it happens.

Here's a pic of the block I'm talki ng about geoff.
Attached Images
File Type: jpg 20180223_132329.jpg (208.3 KB, 69 views)
MACPLUMB777 likes this.
chonkie is offline   Reply With Quote
Old 02-23-2018, 04:48 PM   #7
Junior Member
 
Join Date: Feb 2018
Location: framingham ma
Posts: 10

View geofd's Photo Album My Photos
Default

Quote:
Originally Posted by geofd View Post
I read that when there is no return for domestic he
there is a fitting that's installed under a lav (I don't know
how to post pics) when the pump on the water heater is on
it turns part of the cw into a hot return/as soon as a fixture is
used it shuts down that valve and it goes back to it origanal state
I will get the name of the one I found and post it

check out ready temp.com
Thanks chonkie....

that was something else I was wondering thanks for all the info!!!!!

Last edited by geofd; 02-23-2018 at 06:23 PM.. Reason: more info
geofd is offline   Reply With Quote
Old 02-23-2018, 05:08 PM   #8
Senior Member
 
Debo22's Avatar
 
Join Date: Feb 2015
Location: Orange County, CA
Posts: 2,555

View Debo22's Photo Album My Photos
Default

Quote:
Originally Posted by chonkie View Post
I remember that discussion. After taking one apart and testing it, we did conclude that it is not just a simple check valve and it actually closes off when the h2o reaches a certain temp. Don't know what the temp is but it happens.

Here's a pic of the block I'm talki ng about geoff.
Grundfos comfort system, it's designed to shut off at about 105 degrees. I got a call a few years ago where the homeowners complaint was when she turned cold water on at kitchen sink it was hot for about 2 minutes. A new bypass valve solved that problem.
chonkie and MACPLUMB777 like this.
Debo22 is offline   Reply With Quote
Old 06-07-2018, 08:36 AM   #9
Senior Member
 
chonkie's Avatar
 
Join Date: Jul 2014
Location: North Texas
Posts: 3,118

View chonkie's Photo Album My Photos
Default

Quote:
Originally Posted by anytimehvac View Post
A crossover valve is basically a defective or faulty mixing valve that allows cold water into the hot water pipes and/or hot water into the cold water pipes. This type of mixing valve is usually found wherever a hot and cold pipe meets at a fixture in a central heating system.

Next post of yours needs to be an intro. And how is a valve that is designed to allow hot water into the cold side "basically a defective or faulty valve"?
MACPLUMB777 likes this.
chonkie is offline   Reply With Quote
Old 06-07-2018, 10:19 AM   #10
Super Moderator
 
Join Date: Jun 2008
Location: Houston, Texas
Posts: 1,694

View MACPLUMB777's Photo Album My Photos
Talking

Default Why Post An Intro?
Quote:
An intro is requested from all new members. In case you missed it, here is the link. https://www.plumbingzone.com/f3/.

The PZ is for Plumbing Professionals ( those engaged in the plumbing profession)

Post an intro and tell our members where you are from, yrs in the trade, and your area(s) of expertise in the plumbing field.

This info helps members who are waiting to welcome you to the best plumbing site there is.

We look forward to your valuable input.
__________________
Jerry Mac
MAC SALES 777
832-409-5850
[email protected]
MACPLUMB777 is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Delta shower valve has no pressure The Dane Residential Plumbing 32 03-08-2018 11:41 PM
Moentrol with 3 function transfer valve trim? The Dane Plumbing Material and Products 2 01-20-2018 05:58 AM
Knife valve prior to backwater valve JohnnieSqueeze General Plumbing Discussion 1 12-03-2016 08:02 PM
Cross Connection Bill Residential Plumbing 10 02-04-2016 02:48 PM
Tub/Shower Valve Installation Snowyman800 Plumbing Pictures 30 01-09-2016 02:17 PM


All times are GMT -4. The time now is 04:57 AM.


Powered by vBulletin® Version 3.8.8
Copyright ©2000 - 2020, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.1
vBulletin Security provided by vBSecurity v2.2.2 (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
User Alert System provided by Advanced User Tagging (Pro) - vBulletin Mods & Addons Copyright © 2020 DragonByte Technologies Ltd.
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | ElectricianTalk.com | HVACSite.com | PaintTalk.com | RoofingTalk.com