I have a General Typhoon 2512 Jetter that has 2500 psi. I wanted to know if it is safe to use a 1/4" hose on it for small lines? What adapters do I need and what is the safest way to do this? Please let me know as soon as you can. Thanks.
Drain Cleaner is offline   Reply With Quote
Join Contractor Talk

Join the #1 Plumbers Forum Today - It's Totally Free!

PlumbingZone.com - Are you a Professional Plumbing Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for plumbers to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that PlumbingZone.com is a great community to join. Best of all it's totally free!

Join PlumbingZone.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Old 08-18-2010, 08:06 PM   #2
Moderator
 
Airgap's Avatar
 
Join Date: Dec 2008
Posts: 3,318

View Airgap's Photo Album My Photos
Default

Quote:
Originally Posted by Drain Cleaner View Post
I have a General Typhoon 2512 Jetter that has 2500 psi. I wanted to know if it is safe to use a 1/4" hose on it for small lines? What adapters do I need and what is the safest way to do this? Please let me know as soon as you can. Thanks.
I am no jetter expert by any stretch of the imagination....But I believe I might take a look in the owners manual....Just a thought....
__________________
AG..Keepin' the good water from the bad water....
Airgap is offline   Reply With Quote
The Following User Says Thank You to Airgap For This Useful Post:
Protech (08-18-2010)
Old 08-18-2010, 08:09 PM   #3
Senior Member
 
RealLivePlumber's Avatar
 
Join Date: Jun 2008
Location: NJ
Posts: 2,429

View RealLivePlumber's Photo Album My Photos
Default

Quote:
Originally Posted by Drain Cleaner View Post
I have a General Typhoon 2512 Jetter that has 2500 psi. I wanted to know if it is safe to use a 1/4" hose on it for small lines? What adapters do I need and what is the safest way to do this? Please let me know as soon as you can. Thanks.
Why don'tcha just stick it on there and try it out?

Never be afraid. If your scared, get a dog.


Let us know what happens.
__________________
RealLivePlumber
You can make it happen, you can watch it happen, or you can wonder wtf happened.
Phil Harris 2009
RealLivePlumber is online now   Reply With Quote
Old 08-18-2010, 09:11 PM   #4
Senior Member
 
Plumbergeek's Avatar
 
Join Date: Aug 2010
Location: SW Georgia
Posts: 132

View Plumbergeek's Photo Album My Photos
Default

I have a MyTana M30 MaxBlast that's 3000psi@ 4.5gpm it came with a 1/8" hose. I use it in 1 1/4" lines but I keep the pressure to no more than 1500psi
__________________


Plumbergeek is offline   Reply With Quote
The Following User Says Thank You to Plumbergeek For This Useful Post:
Drain Cleaner (08-19-2010)
Old 08-18-2010, 09:15 PM   #5
٩(͡๏̯͡๏)۶
 
Protech's Avatar
 
Join Date: Sep 2008
Location: Polk County, Florida
Posts: 7,167

View Protech's Photo Album My Photos
Send a message via Skype™ to Protech
Default

You will have to know the pumps gpm to rpm curve. I realize that most positive displacement pumps have what looks like a linear relationship, but in actuality there is a slight curve in the performance due to "slippage". That said, if you can’t get the pumps GPM down to 5gpm you will end up damaging the pump or the hose. The second issue is that even if the pump will idle low enough, it still has to have enough torque to stay running while pressurizing the hose. If it doesn't have enough low end torque it may stall the pump. Also, depending on how many plungers that pump has, the output may become pulsed due to the low rpm. You could get around that by building and big air chamber out of some steel pipe, a tee, a cap, and an increaser coupling if you are desperate to use that hose on that jetter.

If the pump can't be throttled down low enough you can make a dump rig. It would consist of a tee fitting and an extra hose with a nozzle to dump the excess flow. You can just put the dump hose out on the street inside a steel pipe and anchor everything down.

To summarize: Not the most fast and efficient way, but in a pinch it is possible.
Protech is offline   Reply With Quote
Old 08-18-2010, 09:17 PM   #6
Senior Member
 
Phat Cat's Avatar
 
Join Date: Apr 2009
Posts: 5,106

View Phat Cat's Photo Album My Photos
Default

Did I miss the intro?

Seems to me that a professional drain cleaner would know the answer to that question . . . meh?

So many questions in life and so little answers.
__________________
All that is necessary for the triumph of evil is that good men do nothing. – Edmund Burke
Phat Cat is offline   Reply With Quote
Old 08-18-2010, 09:24 PM   #7
٩(͡๏̯͡๏)۶
 
Protech's Avatar
 
Join Date: Sep 2008
Location: Polk County, Florida
Posts: 7,167

View Protech's Photo Album My Photos
Send a message via Skype™ to Protech
Default

I seriously doubt any DIYer could even get his hands on a typhoon.

And no disrespect to the new guy, but most drain cleaners out there don't have much knowledge of hydraulic theory. They are just guys willing to get chitty to get by. I know there are quite a few plumbers who got into the industry by doing drain cleaning.

To the new guy: POST AN INTRO. you won't get much help here until you do. It's just how we do things here. After the intro, you'll find people will warm up to you

Quote:
Originally Posted by PlumbCrazy View Post
Did I miss the intro?

Seems to me that a professional drain cleaner would know the answer to that question . . . meh?

So many questions in life and so little answers.
Protech is offline   Reply With Quote
Old 08-18-2010, 11:34 PM   #8
Senior Member
 
Phat Cat's Avatar
 
Join Date: Apr 2009
Posts: 5,106

View Phat Cat's Photo Album My Photos
Default

Quote:
Originally Posted by Protech View Post
I seriously doubt any DIYer could even get his hands on a typhoon.

And no disrespect to the new guy, but most drain cleaners out there don't have much knowledge of hydraulic theory. They are just guys willing to get chitty to get by. I know there are quite a few plumbers who got into the industry by doing drain cleaning.

To the new guy: POST AN INTRO. you won't get much help here until you do. It's just how we do things here. After the intro, you'll find people will warm up to you
Seemed an odd question to post on a forum you just joined when General should be able to answer the question for him. With plumbers and drain cleaners spending so much time looking, buying, and selling on E-Bay - nothing anyone has would surprise me.

I'm a cynic.
__________________
All that is necessary for the triumph of evil is that good men do nothing. – Edmund Burke
Phat Cat is offline   Reply With Quote
Old 08-19-2010, 10:12 AM   #9
Junior Member
 
Join Date: Aug 2010
Posts: 2

View Drain Cleaner's Photo Album My Photos
Default

the problem is that I can't get the jetter to produce less than 2000 psi and 12 gallons per minute. In stead of having to buy a small jetter for kitchen sinks, I wanted to use that one I have. I have dealt with General tons of times and each time their representatives tells me something different. Someone else out there must know if there is a adapter or if it is possible to use a 1/4" hose without damaging the machine.
Drain Cleaner is offline   Reply With Quote
Old 08-19-2010, 10:17 AM   #10
٩(͡๏̯͡๏)۶
 
Protech's Avatar
 
Join Date: Sep 2008
Location: Polk County, Florida
Posts: 7,167

View Protech's Photo Album My Photos
Send a message via Skype™ to Protech
Default

Go back up and read post #5

Quote:
Originally Posted by Drain Cleaner View Post
the problem is that I can't get the jetter to produce less than 2000 psi and 12 gallons per minute. In stead of having to buy a small jetter for kitchen sinks, I wanted to use that one I have. I have dealt with General tons of times and each time their representatives tells me something different. Someone else out there must know if there is a adapter or if it is possible to use a 1/4" hose without damaging the machine.
Protech is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
1 3/8 inch thread ??? stillaround Plumbing Material and Products 1 04-21-2010 06:29 PM
Jetter Hose Mr Slate Drain and Sewer Cleaning 3 02-13-2010 01:35 AM
cutting 4 inch duram steel pipe Master Mark General Plumbing Discussion 34 12-20-2009 04:31 PM
4 inch pvc check valves Bollinger plumber General Plumbing Discussion 9 04-14-2009 12:07 PM
Large water mains. Ron Commercial Plumbing 10 08-19-2008 11:10 PM


Top of Page | View New Posts

All times are GMT -4. The time now is 08:00 AM.


Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2012, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.6.0 RC 2
Plumbing Zone © 2010The Building Network LLC