I have a General Typhoon 2512 Jetter that has 2500 psi. I wanted to know if it is safe to use a 1/4" hose on it for small lines? What adapters do I need and what is the safest way to do this? Please let me know as soon as you can. Thanks.
|
|
|
|
Join the #1 Plumbers Forum Today - It's Totally Free! PlumbingZone.com - Are you a Professional Plumbing Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for plumbers to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that PlumbingZone.com is a great community to join. Best of all it's totally free! |
|
|
#2 | |
|
Moderator
|
Quote:
![]()
__________________
AG..Keepin' the good water from the bad water.... |
|
|
|
|
| The Following User Says Thank You to Airgap For This Useful Post: | Protech (08-18-2010) |
|
|
#3 | |
|
Senior Member
|
Quote:
Never be afraid. If your scared, get a dog. Let us know what happens.
__________________
RealLivePlumber You can make it happen, you can watch it happen, or you can wonder wtf happened. Phil Harris 2009 |
|
|
|
|
|
|
#4 |
|
Senior Member
|
I have a MyTana M30 MaxBlast that's 3000psi@ 4.5gpm it came with a 1/8" hose. I use it in 1 1/4" lines but I keep the pressure to no more than 1500psi
__________________
|
|
|
|
| The Following User Says Thank You to Plumbergeek For This Useful Post: | Drain Cleaner (08-19-2010) |
|
|
#5 |
|
٩(͡๏̯͡๏)۶
|
You will have to know the pumps gpm to rpm curve. I realize that most positive displacement pumps have what looks like a linear relationship, but in actuality there is a slight curve in the performance due to "slippage". That said, if you can’t get the pumps GPM down to 5gpm you will end up damaging the pump or the hose. The second issue is that even if the pump will idle low enough, it still has to have enough torque to stay running while pressurizing the hose. If it doesn't have enough low end torque it may stall the pump. Also, depending on how many plungers that pump has, the output may become pulsed due to the low rpm. You could get around that by building and big air chamber out of some steel pipe, a tee, a cap, and an increaser coupling if you are desperate to use that hose on that jetter.
If the pump can't be throttled down low enough you can make a dump rig. It would consist of a tee fitting and an extra hose with a nozzle to dump the excess flow. You can just put the dump hose out on the street inside a steel pipe and anchor everything down. To summarize: Not the most fast and efficient way, but in a pinch it is possible. |
|
|
|
|
|
#6 |
|
Senior Member
|
Did I miss the intro?
![]() Seems to me that a professional drain cleaner would know the answer to that question . . . meh? So many questions in life and so little answers. ![]()
__________________
All that is necessary for the triumph of evil is that good men do nothing. – Edmund Burke |
|
|
|
|
|
#7 |
|
٩(͡๏̯͡๏)۶
|
I seriously doubt any DIYer could even get his hands on a typhoon.
And no disrespect to the new guy, but most drain cleaners out there don't have much knowledge of hydraulic theory. They are just guys willing to get chitty to get by. I know there are quite a few plumbers who got into the industry by doing drain cleaning. To the new guy: POST AN INTRO. you won't get much help here until you do. It's just how we do things here. After the intro, you'll find people will warm up to you ![]() |
|
|
|
|
|
#8 | |
|
Senior Member
|
Quote:
I'm a cynic.
__________________
All that is necessary for the triumph of evil is that good men do nothing. – Edmund Burke |
|
|
|
|
|
|
#9 |
|
Junior Member
|
the problem is that I can't get the jetter to produce less than 2000 psi and 12 gallons per minute. In stead of having to buy a small jetter for kitchen sinks, I wanted to use that one I have. I have dealt with General tons of times and each time their representatives tells me something different. Someone else out there must know if there is a adapter or if it is possible to use a 1/4" hose without damaging the machine.
|
|
|
|
|
|
#10 | |
|
٩(͡๏̯͡๏)۶
|
Go back up and read post #5
Quote:
|
|
|
|
|
![]() |
| Thread Tools | |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| 1 3/8 inch thread ??? | stillaround | Plumbing Material and Products | 1 | 04-21-2010 06:29 PM |
| Jetter Hose | Mr Slate | Drain and Sewer Cleaning | 3 | 02-13-2010 01:35 AM |
| cutting 4 inch duram steel pipe | Master Mark | General Plumbing Discussion | 34 | 12-20-2009 04:31 PM |
| 4 inch pvc check valves | Bollinger plumber | General Plumbing Discussion | 9 | 04-14-2009 12:07 PM |
| Large water mains. | Ron | Commercial Plumbing | 10 | 08-19-2008 11:10 PM |