Old 06-18-2008, 01:22 PM   #1
Senior Member
 
GrumpyPlumber's Avatar
 
Join Date: Jun 2008
Location: MA
Posts: 572

View GrumpyPlumber's Photo Album My Photos
Default Just get a better toilet!

This ones for the books.
I did an estimate yesterday for a referral from an existing customer.
It's a pending home sale and they needed an estimate on how much it would cost to repair the downstairs bath that had obviously been diy'ed
Real estate agent was present and when I informed her that the slab had to be drilled and a sewage ejector installed...she insisted I was wrong and that all they needed to do was put in a more powerful toilet. (classic)
As you all can imagine, there's no vent for this group...I simply filled the lav and let everyone watch the water level in the toilet slowly drop as the lav drained.

I betcha you guys might be able to figure out what the other problem(s) are...
Attached Images
File Type: jpg Image008.jpg (55.2 KB, 12 views)

Last edited by GrumpyPlumber; 06-18-2008 at 01:26 PM..
GrumpyPlumber is offline   Reply With Quote
Join Contractor Talk

Join the #1 Plumbers Forum Today - It's Totally Free!

PlumbingZone.com - Are you a Professional Plumbing Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for plumbers to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that PlumbingZone.com is a great community to join. Best of all it's totally free!

Join PlumbingZone.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Old 06-18-2008, 01:28 PM   #2
Master Plumber
 
Join Date: Jun 2008
Posts: 1,053

View 22rifle's Photo Album My Photos
Default

If you put in an ejector you will have to vent to atmosphere too huh?

Nice tee on it's side too.

BTW, what about those toilets sitting on an ejector? Would that work here?

Doncha hate working with real estate agents on a home sale? Everything you say is a strike against their interests so it's this big tug of war thing going on.
22rifle is offline   Reply With Quote
Old 06-18-2008, 01:50 PM   #3
Senior Member
 
Join Date: Jun 2008
Posts: 2,411

View Killertoiletspider's Photo Album My Photos
Default

I guess backpitch is better than no pitch?
Killertoiletspider is offline   Reply With Quote
Old 06-18-2008, 03:05 PM   #4
LeMarr Plumbing, Inc.
 
Song Dog's Avatar
 
Join Date: Jun 2008
Location: Carlinville, IL
Posts: 771

View Song Dog's Photo Album My Photos
Default

Funny, she has the solution, just get a better toilet. Its not the problem. I love it (not really) when someone who doesn't have a clue knows more about what i do, than I do.

In Christ,

Song Dog
__________________
Don't Franchise!
Teaching my kids to hunt and shoot-PRICELESS!
Song Dog is offline   Reply With Quote
Old 06-18-2008, 04:21 PM   #5
Senior Member
 
Join Date: Jun 2008
Location: Oklahoma city,Ok
Posts: 376

View threaderman's Photo Album My Photos
Send a message via Yahoo to threaderman
Default

No primer, and is that C.I. or concrete? If so it looks like the hub is supporting the weight of the pipe ,which is a no-no.Also,no ferncos allowed inside the structure ,it should be no-hubs/mission bands.Any one else here call them mission bands?I would think the northern plumbers have or do.
threaderman is offline   Reply With Quote
Old 06-18-2008, 04:24 PM   #6
Senior Member
 
Join Date: Jun 2008
Location: Oklahoma city,Ok
Posts: 376

View threaderman's Photo Album My Photos
Send a message via Yahoo to threaderman
Default

I like to keep the spigot end of a fitting running down-stream as well,if possible.
threaderman is offline   Reply With Quote
Old 06-18-2008, 06:03 PM   #7
Senior Member
 
GrumpyPlumber's Avatar
 
Join Date: Jun 2008
Location: MA
Posts: 572

View GrumpyPlumber's Photo Album My Photos
Default

The san-tee on it's side, the obvious back-pitch in the photo, the fernco clamps with no sleeve, no supports on the 4" PVC , no venting...and yes, I mentioned the "quick-Jon" as well but was immediately shot down by the all knowing R.E. agent who told me a flushometer or power flush would resolve the back-pitch.

When the R.E. agent started talking to me like I didn't know what I was talking about, I just said f-ck it and quoted the most expensive alternative...I was hired by the buyer to give them an honest appraisal for negotiating the price down.

The agent might have gotten the Quick-Jon alternative...but seeing as she knows so much more than me I figured she could estimate that option.
GrumpyPlumber is offline   Reply With Quote
Old 06-18-2008, 10:07 PM   #8
residential service
 
Join Date: Jun 2008
Location: Birmingham, AL
Posts: 1,811

View smellslike$tome's Photo Album My Photos
Default

As soon as she started disputing my word I would have retrieved my state certified master plumber certification card from my wallet and said something like, "lady you have absolutely no idea what you are talking about and unless you can show me one of these with your name on it you need to shut your mouth and leave the plumbing diagnostics to a professional. Anything less than what I have said is necessary will simply be more hackery of the sort that has created this nightmare to begin with. Now do we need to get the city out here to offer their second opinion on what needs to be done because it's the inspectors job to protect home owners, both old and new, by insuring that certain minimum building standards are met with respect to building construction which would certainly include plumbing among many other things. I've got them right here on speed dial and I'll be happy to call them for you?"

Of course I would never have thought of such an awesome response as that while I was standing there. It would have come to me in the middle of the night after I had fumed about it all evening .
smellslike$tome is offline   Reply With Quote
Old 06-19-2008, 12:27 AM   #9
Junior Member
 
Join Date: Jun 2008
Location: marc in calgary, really?
Posts: 4

View marc in calgary's Photo Album My Photos
Default

that sounds about right for me too.
They're called ferncos here in Canada, I find the easiest way out of this sort of situation begins with the statement... "Plumbing code mandates that we do bla bla bla..." and when realtors "back talk" to me, I state again, "The Plumbing Code..." once they realize they're not arguing with me, but with "the powers that be" they'll also get that I'm not above calling the real estate board here to talk trash about a plumber wan-a-be.
and then they'll not be able to sell a house stating there is a bathroom in the basement, why? because it isn't approved.

well, good thing I'm not running for election.
marc in calgary is offline   Reply With Quote
Old 06-21-2008, 11:04 PM   #10
Senior Member
 
Join Date: Jun 2008
Location: S.E. Idaho
Posts: 800

View Herk's Photo Album My Photos
Default

In a case like this, it might just be prudent to call in an inspector and have him red tag it and then it won't be habitable until it's fixed properly.
Herk is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Hot water to toilet ronin Residential Plumbing 1 11-29-2008 11:18 PM
Toilet Leaking boongoon General Plumbing Discussion 20 10-29-2008 11:49 PM
Cell Phone In Toilet DUNBAR PLUMBING General Plumbing Discussion 13 10-21-2008 01:18 AM
Toilet of choice Cal Plumbing Material and Products 21 07-31-2008 09:55 PM