If possible, could someone post pics of cell core failure? I have yet to experience it but since it is being mentioned so often, I think it might be more than just rumors.
plbgbiz is offline   Reply With Quote
The Following User Says Thank You to plbgbiz For This Useful Post:
plumbpro (01-25-2011)

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Old 01-25-2011, 06:43 PM   #2
Moderator
 
Bill's Avatar
 
Join Date: Jun 2008
Location: I have no idea!
Posts: 6,451

View Bill's Photo Album My Photos
Send a message via Yahoo to Bill
Default

I did not get pix, but I had one failure. It was a 3" foam core riser glued to a test flange from a tee wey. The air was entering between the pvc walls (Inner and outer) at the wey and traveling up through the foam core and escaping out the top edge of the pipe. I replaced it with sch 40 and was fine. I used foam core everywhere else with no problems. When its glued between fittings the air stays traped inside, but on a closet riser it will seep out.

This happened to me about a week ago.
__________________
Virginia Plumbing Codes
Virginia Department of Licensing


Ones intellect can often be summed up by his own words
Bill is offline   Reply With Quote
The Following User Says Thank You to Bill For This Useful Post:
plbgbiz (01-25-2011)
Old 01-25-2011, 09:45 PM   #3
The Pipe Whisperer
 
ranman's Avatar
 
Join Date: Jan 2010
Location: gilbert az
Posts: 393

View ranman's Photo Album My Photos
Default

been there. it was a pain to find
__________________

ranman is offline   Reply With Quote
Old 01-29-2011, 08:59 PM   #4
Moderator
 
Tommy plumber's Avatar
 
Join Date: Feb 2010
Location: Florida
Posts: 8,789

View Tommy plumber's Photo Album My Photos
Default

I don't have pics of any cell core failures. Chief plumbing inspector of my county tells me that a local plumbing contractor installed some town homes (2-story) and used cell core for the W/C risers. After occupants were in homes for a while, they noticed stains under upstairs bathrooms. Long story short, it was when the upstairs toilets were flushed, the water was wicking out of the cell core and forming droplets that eventually leaked down onto ceiling below. Perhaps this isn't often, but once is enough.
__________________
Hire a licensed master plumber.
Tommy plumber is offline   Reply With Quote
Old 01-30-2011, 06:26 PM   #5
Senior Member
 
Join Date: Jan 2009
Location: Southern, Maine
Posts: 485

View Plumbdog's Photo Album My Photos
Default

Think about that for a moment. once the the toilet is flushed the water and all its contents continue down the drain and out of the WC riser any risidual water would be minimal and I doubt that it would be enough to "wick through". More likely a crack in the pipe that someone failed to chase down during testing.

I've seen cracks like this in cell core. A PITA to find during an air test, the air leaking through doesn't make any noise. A spray bottle with bubbles on all the pipe is the best way to track them down.
Plumbdog is offline   Reply With Quote
Old 01-30-2011, 08:26 PM   #6
Moderator
 
Tommy plumber's Avatar
 
Join Date: Feb 2010
Location: Florida
Posts: 8,789

View Tommy plumber's Photo Album My Photos
Default

Quote:
Originally Posted by Plumbdog View Post
Think about that for a moment. once the the toilet is flushed the water and all its contents continue down the drain and out of the WC riser any risidual water would be minimal and I doubt that it would be enough to "wick through". More likely a crack in the pipe that someone failed to chase down during testing.

I've seen cracks like this in cell core. A PITA to find during an air test, the air leaking through doesn't make any noise. A spray bottle with bubbles on all the pipe is the best way to track them down.




Maybe it was a hairline crack. The inspector told me the story a long time ago.
__________________
Hire a licensed master plumber.
Tommy plumber is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Foam Core PVC disaster Bill Plumbing Material and Products 10 01-16-2011 10:07 PM
Cell Core PVC VS. Hot Water user2090 Plumbing Pictures 13 06-30-2010 09:13 PM
The Tea Party movement will fail dankman Off Topic 114 03-28-2010 08:33 AM
Would this pass or fail in your jurisdiction SPH Plumbing Pictures 43 01-14-2010 03:28 PM
Cell Phones Song Dog Off Topic 14 07-19-2008 02:25 PM


All times are GMT -4. The time now is 02:28 PM.


Copyright 2000-2014 Escalate Media LP. All Rights Reserved
Our Pro Sites Network
ContractorTalk.com | DrywallTalk.com | ElectricianTalk.com | HVACSite.com | PaintTalk.com | RoofingTalk.com

Search Engine Optimization by vBSEO 3.6.1