Old 02-05-2010, 05:14 PM   #1
www.DunbarPlumbing.com
 
DUNBAR PLUMBING's Avatar
 
Join Date: Sep 2008
Location: NORTHERN KENTUCKY - GREATER CINCINNATI AREA
Posts: 4,492

View DUNBAR PLUMBING's Photo Album My Photos
Default Installing a Water Heater Hooked to a Drain Pipe

WTF??!?!??!?!??!





It's been installed that way since 1920, working I know for some time,

but I would "guess" where the piping 90's into the wall is the culprit.


Just look at the deterioration of that wall and tell me that there isn't a huge pile of of mortar and brick, leaves sitting in that arrangement.


For those of you who are skeptics of "why" I installed that water heater to begin with? How can I prove the corrosion/deterioration of that top of the water heater isn't "normal" ? How do I not look at all the condensation that destroyed the galvanized piping, the lack of no proper access to clean that piping, anything in this laundry list of issues. ???

Well, ask yourself how do you recreate a situation of 40,000 BTU's forcing through a 3" flue at a minimum 300fpm's a second, just using a flame from a match or a simple burning edge of a newspaper....

Neither will act as a true measure of what that water heater is doing.

That's why I'd be hard pressed to believe that even one of you have a Dwyer #460 air meter to gauge what the actual fpms of your last gas water heater install really is.


Then ask me if I didn't check for cold draft and didn't do a force start on the water heater - sealing the draft diverter and the holes at the pipe leading outside to see if I could warm that pipe on this cold winter day to get it to draw.

Telling a customer NO when something they "think" has been operating for 90+ years is grounds for dismissal without income. Showing/proving the situation and instructing/educating the consumer values to both you and them both, especially if you have a camera and document it for the world to see.

Sometimes cause and action work in the element of valued learning, and I've been wanting to make a video of this type of situation for years, because I've entered this dangerous peril many many times with the customers scooting me out the door and me without income.

This is where the honest plumber will always win.


I'm not dumb, I just play dumb on the internet.


There's more to this story unfolding...

Last edited by DUNBAR PLUMBING; 02-05-2010 at 05:26 PM.. Reason: I got ants in my pants!
DUNBAR PLUMBING is offline   Reply With Quote
Join Contractor Talk

Join the #1 Plumbers Forum Today - It's Totally Free!

PlumbingZone.com - Are you a Professional Plumbing Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for plumbers to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that PlumbingZone.com is a great community to join. Best of all it's totally free!

Join PlumbingZone.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Old 02-05-2010, 05:39 PM   #2
Senior Member
 
Join Date: Sep 2008
Location: Newington, CT.
Posts: 246

View trick1's Photo Album My Photos
Default

People look at us funny when we drill a hole in the chimney connector and check draft after the regulator and they look even harder when we are able to check the draft over the combustion chamber.............and we do this for the reason that you just found.

I've seen people end up in hospitals and homes because of a "mysterious" illness when in fact the clay tile liner of their masonry chimney collapsed and caused co poisoning.....

Checking for proper draft is as important as checking for a natural gas leak and that's a fact
trick1 is offline   Reply With Quote
The Following User Says Thank You to trick1 For This Useful Post:
breid1903 (02-06-2010)
Old 02-05-2010, 05:44 PM   #3
Registered Member
 
Join Date: Jun 2009
Posts: 6,437

View TheMaster's Photo Album My Photos
Default

I'm not second guessing you but heres how I would have handled that call. Once I saw that vent all jacked up in the basement thats the 1st thing I would have investigated before i touched it......I usually give a price on the phone for a water heater replacement and tell them once I get to the job and look it over I will tell you if its a normal install and if I find problems will give you an idea of what it will cost to correct it. In this situation you have I would have found out the vent had to be replaced before i touched it. They might would want to change to electric....but now they are kinda trapped with the gas one being they paid you to install it.
TheMaster is offline   Reply With Quote
The Following 4 Users Say Thank You to TheMaster For This Useful Post:
Don The Plumber (02-14-2010), Protech (02-05-2010), Redwood (02-05-2010), stillaround (02-05-2010)
Old 02-05-2010, 06:17 PM   #4
Senior Member
 
stillaround's Avatar
 
Join Date: Mar 2009
Location: Florida
Posts: 3,207

View stillaround's Photo Album My Photos
Default

I agree on that phone skill.
__________________
Government does not solve problems; it subsidizes them.



stillaround is offline   Reply With Quote
Old 02-05-2010, 06:23 PM   #5
Registered Member
 
Join Date: Jun 2009
Posts: 6,437

View TheMaster's Photo Album My Photos
Default

I do not vent anything into a chimney but gas logs. Its not allowed here anymore. I always tell them if the vents not proper it will be extra for sure. With that water heater not drawing the new G.E heater would eventually over heat and the trd pop.
TheMaster is offline   Reply With Quote
Old 02-05-2010, 06:58 PM   #6
SharkBite Certified
 
OldSchool's Avatar
 
Join Date: Jan 2010
Location: Ontario Canada
Posts: 3,593

View OldSchool's Photo Album My Photos
Default

WTF.... who in the hell would have vented that out like that. Time to put in a power vent (side wall venting). Nice call Dunbar
OldSchool is offline   Reply With Quote
The Following 2 Users Say Thank You to OldSchool For This Useful Post:
Don The Plumber (02-14-2010), Redwood (02-05-2010)
Old 02-05-2010, 07:15 PM   #7
www.DunbarPlumbing.com
 
DUNBAR PLUMBING's Avatar
 
Join Date: Sep 2008
Location: NORTHERN KENTUCKY - GREATER CINCINNATI AREA
Posts: 4,492

View DUNBAR PLUMBING's Photo Album My Photos
Default

Quote:
Originally Posted by TheMaster View Post
I'm not second guessing you but heres how I would have handled that call. Once I saw that vent all jacked up in the basement thats the 1st thing I would have investigated before i touched it......I usually give a price on the phone for a water heater replacement and tell them once I get to the job and look it over I will tell you if its a normal install and if I find problems will give you an idea of what it will cost to correct it. In this situation you have I would have found out the vent had to be replaced before i touched it. They might would want to change to electric....but now they are kinda trapped with the gas one being they paid you to install it.

I don't agree with the piping arrangement either, but I'll tell you what I find in these old homes:


Cast-iron piping used as vent pipe

That thick asbestos pipe

Vitrified Clay pipe

Dryer duct

Single wall galvanized pipe over double wall B vent piping

Aluminum duct piping and fittings, all the time

And the list goes on.


What does everyone think of the licensed plumber that installed that 4" cast iron that worked as a usable vent for that water heater that worked for nearly 80+ years???

That's one of our own you know.


There was no double-wall B vent back then, not even single wall galvanized piping that you saw that disintegrated in rapid speed given its conditions of water entering back through that cast iron pipe?

Why did it work for so many years without error?


Good questions that need to be answered.
DUNBAR PLUMBING is offline   Reply With Quote
Old 02-05-2010, 07:17 PM   #8
Senior Member
 
Join Date: Jul 2009
Location: Peo, IL
Posts: 1,148

View Colgar's Photo Album My Photos
Default

Quote:
Originally Posted by DUNBAR PLUMBING View Post

Why did it work for so many years without error?

I wonder if it ever did work properly.
Colgar is offline   Reply With Quote
Old 02-05-2010, 07:27 PM   #9
Registered Member
 
Join Date: Jun 2009
Posts: 6,437

View TheMaster's Photo Album My Photos
Default

People are trying to make their homes more energy efficient and are sealing up all the cracks......thats all great but then the house cant breathe. Puts them at greater risk. Worse case scenario is the change all the doors,windows,add insulation and weather strip and caulk every opening and then leave the old furnace to fill the house full of deadly gas
TheMaster is offline   Reply With Quote
Old 02-05-2010, 07:33 PM   #10
Senior Member
 
Plumber Jim's Avatar
 
Join Date: Jun 2008
Location: Colorado
Posts: 1,800

View Plumber Jim's Photo Album My Photos
Default

whenever is see venting that's not right no matter how long it is said to have worked I don't touch a thing till i get a signed contract to fix it so it is right with todays code. If someone dies it won't be on me.
Plumber Jim is online now   Reply With Quote
Reply

Tags
electric water heater, gas to electric, water heater, water heater conversion

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
How do u pipe water heaters flex or hard pipe? arkyplumber General Plumbing Discussion 77 07-21-2011 06:06 PM
American Water Heater Company - Craftmaster - Whirlpool Water Heater - DEFECTIVE DUNBAR PLUMBING General Plumbing Discussion 56 03-14-2010 11:54 PM
Hard pipe gas line all the way to the water heater Shadow Sabre General Plumbing Discussion 22 10-17-2009 10:28 PM
Bathroom Sink/ Drain Pipe (Drain Pipe broke leading to ground) bli182nk General Plumbing Discussion 4 01-12-2009 10:36 AM
Spigot not working after installing water heater AceStalone Residential Plumbing 2 12-16-2008 09:54 PM


Top of Page | View New Posts

All times are GMT -4. The time now is 01:01 AM.


Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2012, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.6.0 RC 2
Plumbing Zone © 2010The Building Network LLC