Plumbing Zone - Professional Plumbers Forum
PLUMBERS, CLICK HERE AND JOIN OUR COMMUNITY TODAY...IT'S FREE!

Go Back   Plumbing Zone - Professional Plumbers Forum > Plumbing Tools, Products & Safety > Plumbing Tools and Equipment

Reply
 
Thread Tools Display Modes
Old 07-16-2008, 05:40 PM   #1
LeMarr Plumbing, Inc.
 
Song Dog's Avatar
 
Join Date: Jun 2008
Location: Carlinville, IL
Posts: 771

View Song Dog's Photo Album My Photos
Default Press Tools?

Whos got them and what maker do you have? Also, about how much did it run you.
I am looking for one that has 1/2 to 1" copper and will do that in pex also with different jaws.
Thanks ahead of time.

In Christ,

Song Dog
__________________
Don't Franchise!
Teaching my kids to hunt and shoot-PRICELESS!
Song Dog is offline   Reply With Quote
Join Contractor Talk

Join the #1 Plumbers Forum Today - It's Totally Free!

PlumbingZone.com - Are you a Professional Plumbing Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for plumbers to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your specialty is you'll find that PlumbingZone.com is a great community to join. Best of all it's totally free!

Join PlumbingZone.com - Click Here JOIN FOR FREE


Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. PlumbingZone.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Old 07-16-2008, 06:51 PM   #2
Senior Member
 
Join Date: Jun 2008
Posts: 2,411

View Killertoiletspider's Photo Album My Photos
Default

The only one I have used is the Ridgid branded one, which is actually made by Viega, the cordless one is much lighter than the corded one. We don't own one, we rent them when we have a job that we want to use it for, which may became a much smaller number since the fittings failed on the last job we did with Pro Press fittings.
Killertoiletspider is offline   Reply With Quote
Old 07-16-2008, 08:19 PM   #3
Senior Member
 
GrumpyPlumber's Avatar
 
Join Date: Jun 2008
Location: MA
Posts: 572

View GrumpyPlumber's Photo Album My Photos
Default

Quote:
Originally Posted by Killertoiletspider View Post
The only one I have used is the Ridgid branded one, which is actually made by Viega, the cordless one is much lighter than the corded one. We don't own one, we rent them when we have a job that we want to use it for, which may became a much smaller number since the fittings failed on the last job we did with Pro Press fittings.
Nope, won't say it...you know my thoughts on them.
GrumpyPlumber is offline   Reply With Quote
Old 07-16-2008, 09:31 PM   #4
Senior Member
 
Plumberman's Avatar
 
Join Date: Jul 2008
Location: Louisiana
Posts: 2,604

View Plumberman's Photo Album My Photos
Default

Just curious.. The o-rings failed? The reason why I ask is because my boss has talked about doing some small repipes with the Pro-Press. I have had a little dealings with it when I first started service but its been awhile....
__________________
Quote:
Originally Posted by Mississippiplum
Don't you think it's time to come up with something new?
Quote:
Originally Posted by U666A
"Redundancy department; department of redundancy"
Chad-LJP 6656-LMG Installer/Brazer
UA Local 659
Plumberman is offline   Reply With Quote
Old 07-16-2008, 09:35 PM   #5
Senior Member
 
Join Date: Jun 2008
Posts: 2,411

View Killertoiletspider's Photo Album My Photos
Default

Quote:
Originally Posted by Plumberman View Post
Just curious.. The o-rings failed? The reason why I ask is because my boss has talked about doing some small repipes with the Pro-Press. I have had a little dealings with it when I first started service but its been awhile....
We used pro press on some water feeds for gigantic printing presses, and the constant vibration works the crimps loose on roughly a monthly basis, re-crimping the fittings is a temp fix, but we will be re-piping the presses in December when they shut the presses down for maintenance.
Killertoiletspider is offline   Reply With Quote
Old 07-16-2008, 09:43 PM   #6
Senior Member
 
Plumberman's Avatar
 
Join Date: Jul 2008
Location: Louisiana
Posts: 2,604

View Plumberman's Photo Album My Photos
Default

In a stable enviroment they work pretty well then I take it? Im kind of leary of them myself. I guess I just came up sweating and I dont want to do anything else unless there is no other way...
__________________
Quote:
Originally Posted by Mississippiplum
Don't you think it's time to come up with something new?
Quote:
Originally Posted by U666A
"Redundancy department; department of redundancy"
Chad-LJP 6656-LMG Installer/Brazer
UA Local 659
Plumberman is offline   Reply With Quote
Old 07-16-2008, 09:48 PM   #7
Senior Member
 
Join Date: Jun 2008
Posts: 2,411

View Killertoiletspider's Photo Album My Photos
Default

Quote:
Originally Posted by Plumberman View Post
In a stable enviroment they work pretty well then I take it? Im kind of leary of them myself. I guess I just came up sweating and I dont want to do anything else unless there is no other way...
I don't know, I haven't seen one installed long enough to have a good opinion. We have never installed one where we do not have access to it either, mostly we have used them coming off of risers that don't get a good shutdown, and we go back to soldered fittings right after the isolation valve.
Killertoiletspider is offline   Reply With Quote
Old 07-16-2008, 09:53 PM   #8
Senior Member
 
Plumberman's Avatar
 
Join Date: Jul 2008
Location: Louisiana
Posts: 2,604

View Plumberman's Photo Album My Photos
Default

I know what you mean thats about the only dealings Ive had. When a valve wont hold. Like I said I would rather solder than depend on a mechanical fitting. That way I know its going to hold.
__________________
Quote:
Originally Posted by Mississippiplum
Don't you think it's time to come up with something new?
Quote:
Originally Posted by U666A
"Redundancy department; department of redundancy"
Chad-LJP 6656-LMG Installer/Brazer
UA Local 659
Plumberman is offline   Reply With Quote
Old 07-16-2008, 10:18 PM   #9
Senior Member
 
GrumpyPlumber's Avatar
 
Join Date: Jun 2008
Location: MA
Posts: 572

View GrumpyPlumber's Photo Album My Photos
Default

Quote:
Originally Posted by Killertoiletspider View Post
We used pro press on some water feeds for gigantic printing presses, and the constant vibration works the crimps loose on roughly a monthly basis, re-crimping the fittings is a temp fix, but we will be re-piping the presses in December when they shut the presses down for maintenance.
An exaggerated version of standard shock & seizmic motion on any water piping system, very exaggerated.
I betcha thermal expansion plays an eventual role as well.
My major concern is the O-ring...knowing that flappers & packing washers only last so long, they are at least positioned where they can be replaced.
Once the 1/8" O-rings in those joints start to fail from reaction to treated water, it won't be so good.
GrumpyPlumber is offline   Reply With Quote
Old 07-16-2008, 10:26 PM   #10
Senior Member
 
Join Date: Jun 2008
Posts: 2,411

View Killertoiletspider's Photo Album My Photos
Default

Quote:
Originally Posted by GrumpyPlumber View Post
An exaggerated version of standard shock & seizmic motion on any water piping system, very exaggerated.
I betcha thermal expansion plays an eventual role as well.
I would be far more concerned with PEX in this reference, a simple crimped joint on a materiel that is known to expand and contract at a large margin at low temperature variations, to me the product is a failure waiting to happen.

Rubber can be treated to resist chlorine, which is the major contributor to submerged dry rot in rubber, whether the o-rings in Viega fittings are or not I do not know, I know that we have gotten treated o-rings for use on Sloan valves in the past, and Big Orange flappers are made from chlorinated rubber.
Killertoiletspider is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Tools For The Trade kellybhutchings Plumbing Tools and Equipment 11 11-20-2008 07:25 AM
Tools Ron Plumbing Tools and Equipment 13 10-08-2008 10:03 PM
tools se215 General Plumbing Discussion 6 09-26-2008 05:25 PM
New Stanley Virax Press Tool? Song Dog Plumbing Tools and Equipment 7 07-29-2008 05:34 PM